Duty cycle mass spectrometry
WebIn mass spectrometry: Resonance photoionization …pulsed lasers with very short duty cycles, however, making efficient sample use difficult. (The duty cycle is the ratio of the … WebSep 6, 2016 · Silveira JA, Ridgeway ME, Laukien FH, Mann M, Park MA (2016b) Parallel accumulation for 100 % duty cycle trapped ion mobility-mass spectrometry. Int J Mass Spectrom. doi: 10.1016/j.ijms.2016.03.004 Google Scholar
Duty cycle mass spectrometry
Did you know?
WebThe duty cycle is not a constant for an instrument design but is a mass-dependent function and is least for smaller masses. The method described here is capable of raising the duty … WebJan 1, 2024 · The duty cycle is a critical parameter affecting the sensitivity of analyses by Time-of-Flight Mass Spectrometers with Orthogonal Accelerators (OA-TOFMS). Improving …
WebElectrical, 101 Learning. Duty cycle is the ratio of time a load or circuit is ON compared to the time the load or circuit is OFF. Duty cycle, sometimes called "duty factor," is expressed … WebThis system incorporates the brightest ion source, a segmented quadrupole mass filter with improved selectivity and ion transmission, Advanced Vacuum Technology for improved ion transmission to the Thermo Scientific™ Orbitrap™ mass analyzer, and ETD HD, a higher-capacity ETD fragmentation.
WebThe spectral generation frequency was 33 Hz, over the mass range 45–450 m / z. The FM was a high duty-cycle one (100%), composed of a wafer chip with seven ports, connecting internal channels, an external accumulation loop and was operated under non-excessively high gas flows (7–8 mL min − 1) [28]. WebJan 9, 2024 · However, it is important to consider that the drift tube limits the duty cycle and the dynamic range of the mass spectrometer. 28 An IM scan will have significantly less transients summed per scan, which decreases the dynamic range of the instrument. 29 Therefore, turning the IM off and using this instrument in Q-TOF mode increase the duty ...
WebJun 9, 2000 · Duty cycle is also called Duty Factor and Duty Ratio, and in this context is literally the product of the pulse duration and the pulse repetition frequency (Duration x …
WebThe mechanism of ion trapping, gating and bunching is studied under various conditions. By varying trapping and gating parameters, different modes of operation are achievable: from a 100% duty cycle restoration for a narrow mass range … philippe coacheWebThe duty cycle for recording each mass in the spectrum is generally poor, and the higher the resolution or the wider the mass range the poorer the duty cycle. An array detector allows simultaneous acquisition over a range of masses thereby improving the duty cycle when used to record a spectrum. philippe copinschiWebNov 22, 2011 · Journal of The American Society for Mass Spectrometry ... Typical duty cycle is in the range of 5% to 30% depending on the instrument geometry and ion m/z value. We present here a novel trapping/releasing setup, which offers the duty cycle near 100% over a wide range. Operation in the mass range from m/z 120 to almost 2000 is demonstrated. trulee assisted livingWebDuty Cycle Improvement for a Quadrupole–Time-Of-Flight Mass Spectrometer I.V. Chernushevich, Eur. J. Mass Spectrom. 6, 471–479 (2000) Duty cycle improvement for a … philippe clockWebTriwave Technology, which provides access to the unique benefits of Ion Mobility Spectrometry (IMS) Time-aligned parallel (TAP) fragmentation for first- and second-generation fragmentation structural information in a single experiment; Rapid, exchangeable MALDI/API sources; High-duty cycle (HDC) mode for enhanced sensitivity over a wide … philippe constance horlogeWebApr 6, 2024 · Magnetic Sector Secondary Ion Mass Spectrometry Summary Magnetic sector secondary ion mass spectrometry (SIMS) generates isotopic and elemental information from solid surfaces with depth profiling capabilities to measure the concentration of isotopes and elements as a function of depth into the film. Description philippeconsentino.free.frWebFurther increasing the number of mass windows to eight (figure 4(d)) now completely smoothes the duty cycle to a constant 30% duty cycle. In general, the experimental data is … philippe cohen-solal